Wood, grain, sugar, plastics, metals and many other materials become fuel when they are fine enough and suspended in air. For manufacturers that handle them, a dust explosion is a low-frequency, high-severity loss that can take a plant offline for months. Owners usually ask whether insurance pays. The better question is whether what it pays will be enough.
What recent incidents show
The U.S. Chemical Safety Board is investigating multiple explosions at Horizon Biofuels in Fremont, Nebraska, on July 29, 2025, which killed three people and which the CSB classifies as a combustible dust explosion and fire. In February 2026, the CSB released a safety video on the 2017 explosions at Didion Milling in Cambria, Wisconsin, which killed five employees, injured 14 others and caused more than $15 million in damage. The CSB found Didion had not performed a dust hazard analysis and that dust falling from overhead surfaces fueled a second explosion.
Does commercial property cover it?
Generally, yes. Under the ISO Causes of Loss – Special Form (CP 10 30), covered causes are risks of direct physical loss unless excluded, and explosion is also listed among the specified causes of loss. There is no general explosion exclusion. The form does exclude explosion of steam boilers, pipes, engines or turbines you own or lease, while paying for a resulting fire or combustion explosion, and it excludes mechanical breakdown. Manuscript and specialty forms vary, so confirm yours.
A triggered policy is not the same as an adequate one. Three gaps show up after dust losses:
- Business income period. Rebuilding process equipment, dust collection and building structure can take longer than a 12-month period of restoration, and extended period of indemnity is often thin.
- Ordinance or law. A rebuild may have to meet current fire codes and dust standards, adding cost that a like-kind valuation never anticipated.
- Equipment breakdown boundaries. A failure inside a dust collector or dryer can start the sequence. Our briefing on equipment breakdown insurance for manufacturers explains where that coverage ends and property begins.
The regulatory backdrop
OSHA’s revised Combustible Dust National Emphasis Program, CPL 03-00-008, issued January 30, 2023, keeps dust-handling facilities on inspection lists. There is still no OSHA combustible dust standard for general industry; the CSB first recommended one in 2006 and repeated the call in its Didion work. Meanwhile NFPA 660, the Standard for Combustible Dusts and Particulate Solids, took effect December 6, 2024, consolidating NFPA 61, 484, 652, 654, 655 and 664 into one document. Jensen Hughes notes it becomes locally enforceable only as model codes and jurisdictions adopt it, which may take several years, but it already serves as the industry’s best-practice reference.
Underwriters and carrier loss-control engineers use the same reference. A plant that cannot produce a current dust hazard analysis should expect harder questions at renewal, and possibly narrower terms or added engineering recommendations as a condition of coverage. Inspection programs reach the workers’ comp side too; see our note on OSHA’s amputations emphasis program.
A worked example
For illustration only: a Tennessee wood products plant with $18 million in building and equipment values and $9 million in annual business income has a dust collector deflagration that spreads into the main building. Physical damage is covered as explosion. The rebuild, including code-required upgrades, takes 16 months. With a 12-month period of restoration, no extended period of indemnity and a modest ordinance or law limit, the plant keeps four months of lost income, roughly $3 million at that run rate, plus part of the upgrade cost.
A plant checklist
- Identify every combustible dust in the process, and complete or update a dust hazard analysis.
- Track housekeeping on overhead surfaces, not just floors.
- Document isolation and venting on dust collectors and connected ductwork.
- Model a realistic rebuild timeline and set business income and extended period limits to match it.
- Compare ordinance or law limits with current code requirements.
Questions to ask your broker before renewal
- Does our property form contain any explosion, dust or process-related exclusions or sublimits?
- Is our period of restoration long enough for a full equipment and building rebuild?
- What will our carrier’s engineers expect to see on dust controls?
At Peoples First Tennessee, dust exposure runs through our 4-Step Strategic Process: Strategic Discovery of the materials you handle, Risk Assessment of the plant and the policy wording, Solution Design of income and code-upgrade limits, and Ongoing Optimization as NFPA 660 is adopted. For the full program view, see our manufacturing insurance buyer’s guide.
Sources
- U.S. Chemical Safety Board — Horizon Biofuels Explosions
- AIHA — Video depicts 2017 combustible dust explosions at Wisconsin milling facility (Feb. 2026)
- ISO Causes of Loss – Special Form CP 10 30 (specimen, Big “I”)
- OSHA — Combustible Dust: Enforcement (CPL 03-00-008)
- Exponent — New NFPA consolidated standard for combustible dusts
- Jensen Hughes — The Adoption of NFPA 660: A New Era in Combustible Dust Safety
— Ryan Mefford, President & Risk Advisor